Cooling Heating Recirculating Circulator – Precise Temperature Control Systems
GET A FREE QUOTE NOW
Working temperatures from -100℃ to +350℃
Previously unachievable performa
Intelligent temperature control
Maximum process stability and reproducibility
Adop plate heat exchager,Pipeline heating,
the fastest heating and cooling rates.
High cooling power
Large temperature range without fluid change
Closed system,extend thermal fluid lifetime
Incredibly compact
7-inch,10-inch color TFT touch screen display
Comprehensive warning and safety functions
Rapid cooling down from high temperature
Use magnetic drive pump,solve the circulation pump leakage
Structure design
No volatilization of the heat conducting medium at high temperature.
No need to change the heat conducting medium. Continuous control of the temperature
of the below range can be done without rising the pressure: -80℃~190℃, -70℃~220℃,
High repetative of tempeature control effect
Each cycle curve slope is consistent and greatly improve the consistency of production thermostatically control environment.
Circulation Pump
High temperature resistant low temperature magnetic drive pump or a leak-free high and
low temperature shield-driven pump, reduce the risk of system leakage. At the same time
the system has the advantages of low noise and big traffic flow.
Connecting Pipe
LNEYA Dynamic Temperature Control systems in practice
In comparison to other thermal control systems, Dynamic Temperature Control systems
differ sometimes considerably in their thermodynamic characteristics. In practice Dynamic Temperature Control systems offer definite advantages in your work: noticeably shorther heating and cooling times, better stability and reproducibility through the entire process
chain, greater safety for expensive glass reactors and the contained substances, together
with simple and easy operation.
Heat Conduction Medium
It is important to choose the suitable heat conduction medium, to make sure that system
works stably.To choose the suitable medium according to the working temperature of the system is essential.
The package kinds of LNEYA heat conduction medium are 10L, 25L, 30L, 200L. when ordering the heat conduction medium, the heat conduction medium for constant temp
control system, channel, and external circulation equipments.
Technical Parameters:
|
Model |
SUNDI-725WN
|
SUNDI-735WN SUNDI-735N |
SUNDI-755W SUNDI-755 |
SUNDI-775W SUNDI-775 |
SUNDI-7A10W
|
SUNDI-7A15W
|
|
|
Temperature range ℃ |
-70℃~250℃ |
-70℃~250℃ |
-70℃~250℃ |
-70℃~250℃ |
-70℃~250℃ |
-70℃~250℃ |
|
|
Control Mode |
Feed forward PID + Our special dynamic control calculation, PLC controller |
||||||
|
Temp. control |
Option: process temperature control or jacket oil temperature control |
||||||
|
Temp. difference |
Set or control the temperature difference between jacket oil and raw material process |
||||||
|
Program Editor |
20 programs, each program can edit 45 steps. |
||||||
|
Communication protocol |
MODBUS RTU Protocol, RS 485 Interface |
||||||
|
Temperature feedback |
Heat-conducting medium: PT100 Raw material process: PT100 |
||||||
|
Temp. accuracy |
±1℃ |
±1℃ |
±1℃ |
±1℃ |
±1℃ |
±1℃ |
|
|
Heating power |
2500W |
3500W |
5500W |
7500W |
10000W |
15000W |
|
|
Cooling capacity |
250℃ |
2500W |
3500W |
5500W |
7500W |
10000W |
15000W |
|
100℃ |
2500W |
3500W |
5500W |
7500W |
10000W |
15000W |
|
|
20℃ |
2500W |
3500W |
5500W |
7500W |
10000W |
15000W |
|
|
0℃ |
2500W |
3500W |
5500W |
7500W |
10000W |
15000W |
|
|
-20℃ |
2000W |
3000W |
4850W |
6000W |
8200W |
14000W |
|
|
-40℃ |
1300W |
1750W |
2300W |
3100W |
4000W |
8750W |
|
|
-60℃ |
400W |
550W |
750W |
900W |
1200W |
2800W |
|
|
Circulation pump |
Max20L/min 2BAR |
Max35L/min 2BAR |
Max35L/min 2BAR |
Max50L/min 2.5BAR |
Max50L/min 2.5BAR |
Max110L/min 2.5BAR |
|
|
Compressor |
Copeland |
Copeland |
Copeland |
Copeland |
Copeland |
Copeland |
|
|
Expansion valve |
Danfoss |
Danfoss |
Danfoss |
Danfoss |
Danfoss |
Danfoss |
|
|
Oil separator |
Emerson |
Emerson |
Emerson |
Emerson |
Emerson |
Emerson |
|
| Evaporator | KAORI plate heat exchanger |
KAORI plate heat exchanger |
|||||
|
Operation Panel |
7-inch color touch screen controller, temperature curve record, data export to excel format. |
||||||
| Safety protection |
Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. |
||||||
|
Closed |
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. |
||||||
|
Refrigerant |
R-404A R23 |
R-404A R23 |
R404A R23 |
R404A R23 |
R404A R23 |
R404A R23 |
|
|
Connection size |
DN-15 or M24*1.5 |
DN20 or M30*1.5 |
DN20 or M30*1.5 |
DN20 or M30*1.5 |
DN20 or M30*1.5 |
DN-25 M38*1.5 |
|
|
Water-cooled type W (cooling water at 20℃) |
900L/H 1.5bar~4bar |
1200L/H 1.5bar~4bar |
1800L/H 1.5bar~4bar |
2300L/H 1.5bar~4bar |
3200L/H 1.5bar~4bar |
4500L/H 1.5bar~4bar |
|
|
Dimension |
water-cooled |
400*600*1350 |
600*700*1150 |
600*700*1350 |
600*700*1350 |
700*700*1350 |
700*700*1550 |
|
air-cooled |
550*680*1450 |
620*680*1450 |
750*750*1750 |
||||
|
Weight |
water-cooled |
190kg |
235kg |
275kg |
325kg |
370kg |
420kg |
|
air-cooled |
275kg |
320kg |
370kg |
||||
|
Power |
AC 220V 50HZ 5.2kW (max) |
AC 380V 50HZ 8kW (max) |
AC 380V 50HZ 11kW (max) |
AC 380V 50HZ 15kW (max) |
AC 380V 50HZ 20kW (max) |
AC 380V 50HZ 28kW (max) |
|
|
Case material |
SUS 304 |
SUS 304 |
SUS 304 |
SUS 304 |
SUS304 |
SUS304 |
|
|
Optional |
Optional Ethernet interface, configure PC operating software |
||||||
|
Optional |
Optional outside touch screen display controller (separated), the communication line distance is 10 meter. |
||||||
|
Optional power |
220V 60HZ three-phase, 440V~480V 60HZ three-phase |
||||||