NovaEuris provides industrial equipment, instruments, food processing systems and green energy solutions for manufacturers and engineering companies across European markets.

Contact Info

  • Musterstraße 123 , 10115 Berlin
  • support@novaeuris.com

Follow Us

Floor Standing Aerosol Fire Extinguishing System...

Share This Article:

DESCRIPTION

Ground floor aerosol fire protection system is a classical fire suppression system which is origin from Aware Fire in China, This design is inspired by air conditioners, One day, one of our old technician are thinking of how to design the shape of our project aerosol system, then he come out of our office to have a smoking, during about 3 minutes of his smoking, he saw that in from of him on the wall of a house there is a outer conditioner there, then suddenly thought that why not design the ground floor aerosol device like this air conditioner? Then from then on our Ground series of aerosol fire extinguishing device was born, and becomes popular around Mainland of China, and now extend to the world-wide market.

This product is easy to install, just need to place it in the location floor corner in the fire hazards, it no need any yearly inspection.

Floor standing type is for some bigger space, for example: the computer room, Low voltage room, High voltage room etc.

PRODUCT FEATURES

Aware fire ground floor aerosol have the following particular advantages:

  • CE certificated and Test Report support.
  • Effective suppression agent, the density is about 100 to 150 gram per cubic meters.
  • ECO-friendly and Ecologically safe, because its Ozone-layer depletion value is zero, and global warming Potential value is also zero.
  • No need to install it on the wall, just put it in a corner of the room and do debugging system.
  • Low cost in maintenance, and do not need any yearly inspection.
  • Non-pressurized Cylinders.
  • Not require any pipeline and nozzles to work.
  • Halon alternative and even FM200 alternative.
  • Long life service time.

APPLICATION FIELD

  • Generator Room.
  • No break room.
  • Control room.
  • Warehouse.
  • HV room.
  • Data processing rooms.
  • Archives.
  • Library.
  • Museums.
  • UPS and EPS rooms.
  • Battery Room.
  • Power distributing room.
  • server racks.
  • Underground pipe gallery.
  • Cable well, cable trench and cable celler.

HINT

Aerosol system have its advantages and also have its disadvantages, please see below:

  • It is very hot after releasing, so do not touch the cylinder immediately after released, wait until 30 to 60 minutes to handle it.
  • It is not be able to suppress Fire Class D, the metal fire.
  • It can not be used in explosive place and crowded places.

REMARKS

We have some private files to support:

  • Files of MSDS material safety data sheet.
  • Catalogue and Brochure.
  • Installation Instruction.
  • Data Sheet and Model Number.
  • Installation Reference.

Reposted for informational purposes only. Views are not ours. Stay tuned for more.

Leave a Comment